CONTAINERISED WASTE INCINERATOR Incinerator Items/Model HICLOVER TS150(PLC) Picture   Burn Rate (Average) 100-150 kg/hour Feed Capacity(Average) 300kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 1500Liters(1.5m3) Internal Dimensions 1500x1000x1000mm Secondary Chamber 750Liters(0.75m3) Smoke Filter Chamber Wet Scrubber Feed Mode Manual/Mechanical Voltage 415V 3P …

HICLOVER TS10(PLC) Furnace body type Vertical closed furnace combustion chamber

Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal hospital bed supplies, general wastes Hight Temperature Flue Gas Analysis Instrument, O2/CO/NO/NO2 parameter   Incinerator Items/Model HICLOVER TS10(PLC)   Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary …

HICLOVER YD-30C Mobile Type Incinerators

  Model HICLOVER YD-30C Picture   Feed Capacity Average 30-50 kgs per feed Burning Rate Average 30 kgs per hour Voltage 220V Power 0.59Kw Fuel Natural Gas or Diesel oil Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 10.2-20.0 Kgs/Hour Fuel …

TS1000 Average 1000kg/hour Solid Waste Incineration

  Items/Model TS1000 Picture   Principle Solid Waste Incineration Treatment Burn Rate Average 1000kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Power 8.0Kw Oil Consumption (kg/hour) …

150 KG/HR INCINERATOR PLANT

    Incinerator Items/Model HICLOVER TS150   Burn Rate (Average) 150-200 kg/hour Feed Capacity(Average) 300kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 1500Liters(1.5m3) Internal Dimensions 1500x1000x1000mm Secondary Chamber 750Liters(075m3) Smoke Filter Chamber Yes The products of combustion from 出e prim缸y chamber will exhaust into the secondary chamber located directly above the prima叩 chamber for treatmen t within the secondary  chamber. Adrutional heat and 出r 缸e added to promote  combustion in the gaseous phase of  minimum tempera阳re of 850°C thus ensuring complete combustion of volatile and solid particulates . The whole system is controlled and processed by a Central Logic Control System. Incinerator is a beat treatment process of Biomedical waste under high temperatures m 幻d of combustion  of organic substanee to be broken down into i ts chemical component. MANUAL LOAD PYROLYTIC INCINERATOR DESCRIPTION ・ 1.Horizontal cylindrical solid hearth refractory Lined primary combustion chamber resistant to high temperatures . 2.I o何combustion air supply fan, distribution system and automatic control. 3.2 off diesel -fired ignition bumer -temperature controlled . …

MEDICAL WASTE INCINERATOR WITH CAPACITY 500Kg/h

*Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature Thermometer *CE/ISO certification,etc     Incinerator Items/Model HICLOVER TS500(PLC)   Burn Rate …

Waste Incinerator HICLOVER TS30(PLC)

  Incinerator Items/Model HICLOVER TS30(PLC) Burn Rate (Average) 30-50 kg/hour Feed Capacity(Average) 60kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V 2P Power 0.5Kw Burner Type Italy …

INCINERATOR AT NAIROBI SAFARI WALK

Vertical closed furnace combustion chamber incinerator   Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal hospital bed supplies, general wastes.   10-20kg/time (daily burn 3-6times, each time consume about 1 hour) total daily waste capacity 120 kg   Incinerator Items/Model HICLOVER TS10(PLC)   Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode …

HOSPITAL WASTE INCINERATOR 50-60KG / HR

Incinerator Items/Model HICLOVER TS30(PLC)   HICLOVER TS50(PLC)   HICLOVER TS100(PLC)   Burn Rate (Average) 30-50 kg/hour 50-100 kg/hour 100-150 kg/hour Feed Capacity(Average) 60kg/feeding 100kg/feeding 350kg/feeding Control Mode PLC Automatic PLC Automatic PLC Automatic Primary Combustion Chamber 330L(0.33M3) 560L(0.56M3) 1810L(1.81M3) Internal Dimensions 75x75x60cm …