General waste incinerator with automated feeding system

a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components.  b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions.  solid waste incinerator for medical waste disposal china incinerators Principle Medical Waste Incineration Treatment Burn Rate Average 1000-1500 kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter  Internal Dimensions 400*120*100 cm d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated.  “• Heavy steel construction.The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. • Fixed hearth geometry and starved air gasification operational mode.  • Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm.  • Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.  • Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints. m. incorporate an Air Pollution Control System suitable for basic emission control  n. have a thermal efficiency of not less than 85%.  o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets p. have very low levels of unburned material in the slag q. include a supplement fuel source and storage unit (e.g., diesel tank),  “r.  proposals shall include the fuel consumption at the rated capacity be CE Certified, meet relevant British, EU or American Standards, or equivalent. and cool down cycle will take place overnight. • The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall be capable of using electricity as the primary power source.                 Nanjing Clover …

Industrial hazardous and nonhazardous waste and medical infectious waste

Industrial hazardous and nonhazardous waste and medical infectious waste   Incinerator Items/Model HICLOVER TS500(PLC) HICLOVER TS300(PLC) Burn Rate (Average) 500-600 kg/hour 300-500 kg/hour Feed Capacity(Average) 600kg/feeding 400kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 3000Liters(3.0m3) 2000Liters(2.0m3) Internal Dimensions 2100x1200x1200mm 1700x1200x1000mm Secondary Chamber 1500Liters(1.5m3) 1000Liters(1.0m3) Smoke Filter Chamber Yes …

industrial waste incinerator

Items/Model TS2000 (Top Feeding) Principle Waste Incineration Treatment Burn Rate Average 500-600kg/hour Feed Capacity Average 4500kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 7700Liter (7.7m3) Internal Dimensions 5000*1400*1100 mm Secondary Chamber 4000Liter (4.0m3) Feed Mode Manual/Forklift/Crane   Description Brand Model Fuel Type Waste Incinerator HICLOVER TS2000 Oil/Gas *Primary combustion chamber *Secondary combustion chamber * Stainless Steel chimney *Auto PLC control …

Vertical closed incinerator combustion chamber

Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves,  protective clothing and infectious and harm venereal hospital bed supplies, general wastes.   Incinerator Items/Model HICLOVER YD300(PLC) HICLOVER YD500(PLC) Burn Rate (Average) 300-500 kg/hour 500-600 kg/hour Feed Capacity(Average) 480kg/feeding 800kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 2400L(2.4M3) 4000L(4.0M3) Internal Dimensions 220x110x100cm 257x147x108cm Secondary Chamber 1200L 1500L Smoke Filter Chamber …

Waste Incinerator Capacity average 30-50 kgs per hour

Waste Incinerator Capacity average 30-50 kgs per hour   Model YD-30C Main Product List   Primary Combustion Chamber     Secondary Combustion Chamber     Mix-Combustion Chamber     Smoke Filter Chamber     Incinerator Control Case (PLC Auto Type)     Chimney:5.0Meters *(upgrade to Stainless Steel, free cost)   …

Waste Incinerator HICLOVER TS100

*Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney  *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature Thermometer *CE/ISO certification,etc Waste Incinerator HICLOVER TS100 Burn Rate (Average) 100-150 kg/hour Feed Capacity(Average) 200kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 1200Liters(1.2m3) Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual   HICLOVER TS100(PLC)               Nanjing Clover Medical Technology Co.,Ltd. Ecolead Technology(Nanjing) Co.,Ltd. Mobile: +86-13813931455(WhatsApp) …

Incinerator Items/Model HICLOVER TS20(PLC)

Main Product List per 01 set Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:5.0Meters  *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 units Oil Tank (if oil fuel): 200Liters Incinerator Items/Model HICLOVER TS20(PLC) Burn Rate (Average) 20-30 kg/hour Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 210L Internal Dimensions 65x65x50cm             Nanjing Clover Medical Technology Co.,Ltd. Ecolead Technology(Nanjing) Co.,Ltd. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com  Email:     sales@hiclover.com  Email:     hicloversales@gmail.com       …

HICLOVER TS300(PLC) PLC Automatic Waste Incinerator

Default: Side Feeding Door Optional: Front/Top Feeding Door,  Wet scrubber Incinerator Items/Model HICLOVER TS300(PLC)   Burn Rate (Average) 300 kg/hour Feed Capacity(Average) 400kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 2000Liters(2.0m3) Internal Dimensions 1700x1200x1000mm Secondary Chamber 1000Liters(1.0m3)                 Nanjing Clover Medical Technology …

INDUSTRIAL WASTE INCINERATORS FOR ALL SITES

    Picture   Feeding Door Location Top/Side Loading Burn Rate (up to) 200-300 kg/hour Control Mode PLC Automatic Primary Combustion Chamber 2000L(2.0M3) Primary Combustion Chamber Internal Dimensions 2000x1200x850mm Secondary Combustion Chamber 1000L(1.0m3) Feed Mode Manual/forklift/crane ***forklift/crane supply by local     …

Medical waste incinerator Burning Rate 100kg/hr

Subject Medical waste incinerator Day Capacity 1000kg Waste Type Medical waste   https://www.hiclover.com/#!/Model-TS100-Medical-Waste-Incinerator-100-150kgs-per-hour-capacity/p/416001748/category=0   Description Brand Model Fuel Type Medical Incinerator HICLOVER TS100 Diesel Oil/Natural Gas *Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney *Auto PLC control …